Advanced Universal Hardness Tester with Accuracy Load Cell Control

Product Details
Customization: Available
Type: Brinell Cum Rockwell Cum Vickers
Measuring Range: Hb, Hr, Hv
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (15)
  • Advanced Universal Hardness Tester with Accuracy Load Cell Control
  • Advanced Universal Hardness Tester with Accuracy Load Cell Control
  • Advanced Universal Hardness Tester with Accuracy Load Cell Control
  • Advanced Universal Hardness Tester with Accuracy Load Cell Control
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company profile & Certificates
  • FAQ
Overview

Basic Info.

Model NO.
BRV-250T
Application
Metal, Plastic, Ceramics and Glass, Stone
Standard
ISO, ASTM, GB/T
Warranty
1 Year
Mobility
Desktop
Calibrating Method
Length Scale and Hardness Block
Rated Voltage
220V (110V for Optional)
Support Language
English or Chinese
Customized
Customized
Product Name
Touch Screen Universal Hardness Tester Good Price
Display
8′′ Touch Screen
Quality Judgement Function
Yes
Easy Calibration Function
Yes
Data Output
USB Interface or Software System
Function
Brinell / Rockwell / Vickers Hardness Test
Test Force
5 - 250kgf
Transport Package
Plywood Case
Specification
560x260x800mm
Trademark
EBP
Origin
Zhejiang, China
HS Code
9024102000
Production Capacity
200sets/Month

Product Description

Product Description

Advanced Universal Hardness Tester with Accuracy Load Cell Control

 
Advanced Universal Hardness Tester with Accuracy Load Cell Control
 
Main Features:
1) Equipped Brinell, Rockwell, Vickers test methods;
2) 8 inch Touch-screen interface, easy to operate
3) Close loop, with high accuracy load cell, no need install weights;
4) Test force automatic correction, each file is automatically compensated force, improve the accuracy of the force a number of levels;
5) According to GB / ASTM hardness automatic conversion;
6) Rockwell automatically correct curvature radius;
7) Set a password to protect setup parameters, more samples and testing information;
8) Measuring U disk to save data to EXCEL format for easy editing and processing.
9) Modular design for easy maintenance.
Product Parameters

Technical Parameter:

Brinell Scale HBW1/5, 10, 30kgf
HBW2.5/6.25, 15.625, 31.25, 62.5, 187.5kgf
HBW5/25, 62.5, 125, 250kgf
HBW10/100, 250kgf
Rockwell Scales HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRP, HRR, HRS, HRV
Vickers Scale HV5, HV10, HV20, HV30, HV50, HV100, HV120
Test force Rockwell: 60kgf(588N), 100kgf(980N), 150kgf(1471N); Initial test force:10kgf(98N);
Brinell: 5kgf(49N), 6.25kgf(61.25N), 10kgf(98N), 15.625kgf(153.125N), 30kgf(294N), 31.25kgf(306.25N), 62.5kgf(612.5N), 100kgf(980N), 125kgf(1225N), 187.5kgf(1837.5N), 250kgf(2450N)
Vickers: 5kgf(49N), 10kgf(98N), 20kgf(196N), 30kgf(294N), 50kgf(490N), 100kgf(980N), 120kgf(1176N)
Indication accuracy Brinell:  8-650HB (δ/%):±2.5;  Rockwell:  ±0.1HR;  Vickers:    ±2
Repeatability Brinell:  8-650HB (Hcf/%):≤3.0;  Rockwell:  0.5HR;  Vickers: ≤2.5
Hardness range Brinell: 8-650HBW;  Rockwell: 20-100HR;  Vickers: 8-2900HV
Force error <0.5%
Holding Time 0-60s
Minimum measuring unit 0.1µm
Allowed maximum sample size (test space) Allowed max. Sample height in vertical: 220mm(for Rockwell); 170mm(for Vickers & Brinell test mode);
Allowed max. Sample height in horizontal: 200mm
Magnification Eyepiece: 15X,  2.5X (for Brinell), 5X (for Vickers)  (10X, 20X for optional)
Total magnification: 37.5X,  75X
Hardness read Touchable LCD display, USB Flash Disk
Power supply AC220V, 50-60Hz
Implementation of the standards ISO 6508,ASTM E-18,JIS Z2245,GB/T 230.2
ISO 6506,ASTM E10-12,JIS Z2243,GB/T 231.2
ISO 6507,ASTM E92,JIS Z2244,GB/T 4340.2
Dimensions Machine size: 560*260*800mm
Packing size: 730x450x910mm
Weight N/W: 70kg;   G/W: 99kg
 
Standard Accessories (The Packing List):
Part name Quantity Name Quantity
15X eyepiece 1 Brinell indenter diameter of 2.5mm, 5mm, carbide ball 1 each
Vickers indenter 1 Rockwell 1.588 carbide ball indenter 1
Rockwell diamond indenter 1 Objective Lens 2.5 x, 5x 1 each
Hardness block 5pcs Exterior lighting 1
Power line 1 Large, medium, V-test sets 1 each
Sliding test sets 1 U disk (with an Operation manual) 1
Fuse 2A 2 Adjust level screw 4
Dust proof cover 1 Accessory box 1
 
Hardness Testing software:
1. 1.3 megapixel camera, image clearly, indentation measurement automatic/manual measurement
2. Calibration using micrometer or hardness block calibration, can be automatically calibrated
3. The computer automatically measures the image analysis, the hardness software accurate correction and the gradient diagram
4. Hardness according to the national standard and ASTM converted to other hardness; Hardness value statistics and hardness beyond the alarm
5. Automatically generate test report, all test data is always saved for historical query
 
Detailed Photos

Rockwell:

Advanced Universal Hardness Tester with Accuracy Load Cell Control

Brinell:
Advanced Universal Hardness Tester with Accuracy Load Cell Control

Vickers - Knoop:
Advanced Universal Hardness Tester with Accuracy Load Cell Control
Company profile & Certificates
 

Advanced Universal Hardness Tester with Accuracy Load Cell Control

FAQ


Advanced Universal Hardness Tester with Accuracy Load Cell Control

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier